Industrial valves & flow control Dubai, U.A.E.
Specify it
before you
source it.
Industrial valves and flow-control supply from Dubai. For maritime, oil and gas, and industrial projects across the UAE.
Set the duty. Read the limits.
A valve is a set of limits before it is a product. Move the temperature and the rating moves with it. The instrument below reads ASME B16.34 material group 1.1 for carbon steel.
- Class 15019.8bar g
- Class 30051.7bar g
- Class 600103.4bar g
- Class 900155.1bar g
- Class 1500258.5bar g
ASME B16.34 / B16.5 material group 1.1: A105 forged, A216 WCB cast carbon steel. Reference only; confirm against the current edition of the standard and the manufacturer's own rating table.
| °C | Class 150 | Class 300 | Class 600 | Class 900 | Class 1500 |
|---|---|---|---|---|---|
| -29 | 19.8 | 51.7 | 103.4 | 155.1 | 258.5 |
| 38 | 19.8 | 51.7 | 103.4 | 155.1 | 258.5 |
| 50 | 19.5 | 51.7 | 103.4 | 155.1 | 258.5 |
| 100 | 17.7 | 51.5 | 103.0 | 154.5 | 257.5 |
| 150 | 15.8 | 50.3 | 100.6 | 150.9 | 251.5 |
| 200 | 13.8 | 48.6 | 97.2 | 145.8 | 243.0 |
| 250 | 12.1 | 46.3 | 92.6 | 138.9 | 231.5 |
| 300 | 10.2 | 42.9 | 85.8 | 128.7 | 214.5 |
| 325 | 9.3 | 41.4 | 82.8 | 124.2 | 207.0 |
| 350 | 8.4 | 40.0 | 80.0 | 120.0 | 200.0 |
| 375 | 7.4 | 37.8 | 75.6 | 113.4 | 189.0 |
| 400 | 6.5 | 34.7 | 69.4 | 104.1 | 173.5 |
| 425 | 5.5 | 28.8 | 57.6 | 86.4 | 144.0 |
| 450 | 4.6 | 23.0 | 46.0 | 69.0 | 115.0 |
| 475 | 3.7 | 17.4 | 34.8 | 52.2 | 87.0 |
| 500 | 2.8 | 11.8 | 23.6 | 35.4 | 59.0 |
| 538 | 1.4 | 5.9 | 11.8 | 17.7 | 29.5 |
Where the limits bite.
Four duties dominate Gulf specification. Each fails in a different way, and each has a guide. Industries we supply →
District cooling
Dubai runs on chilled water. Every degree of ΔT lost between plant and coil is paid back at the pump.
Desalination & seawater
Ambient Gulf seawater carries roughly 45,000 ppm chloride. Alloy selection stops being a preference.
Oil, gas & petrochemical
The pressure rating is the easy part. Fire, emissions and sour service are three further qualifications.
Steam & process
Saturated steam fixes its own temperature. Reducing, relieving and trapping it are sizing decisions with numbers in them.
What we supply.
Ball, gate, globe, check, butterfly and knife-gate valves; pressure-reducing valves, safety and relief valves, steam traps and strainers; balancing valves and PICV; actuators and dampers; pipeline fittings and connectors, from Dubai for the UAE and the Gulf.

Industrial valves
Ball, gate, globe, check, butterfly and knife-gate: isolation, control and check for every pressure class and body material.

HVAC & district cooling
PICV, static and dynamic balancing, hydronic kits and chiller-plant isolation for chilled-water systems.

Pressure, safety & steam
Pressure-reducing valves, safety and relief valves, steam traps and strainers. The protection layer, sized to the duty.

Actuators, dampers & fittings
Pneumatic and electric actuation, industrial dampers and the pipeline fittings that connect it all.
Product lines we supply.
KITZ, DFT, Etelec, KVC UK Ltd and Vogt. Explore our trading brands.
The documents that decide.
Highlighted rows are the ones the instrument's current selection invokes. Every figure carries the edition caveat, and the glossary explains each document.
| Standard | What it fixes | Invoked |
|---|---|---|
| ASME B16.34 | Pressure and temperature ratings, wall thickness and shell testing for flanged, threaded and welding-end valves. | Yes |
| ASME B16.5 | Flange dimensions, facing, bolting and ratings, NPS ½ through 24. | Yes |
| API 6D | Specification for pipeline and piping valves: design, testing and marking. | No |
| API 598 | Inspection and test: shell, backseat and seat closure, before shipment. | No |
| API 607 / API 6FA | Fire type-testing. Proves a soft-seated valve still seals after the seat has burned out. | No |
| ISO 15848-1 | Fugitive-emission classification of stem sealing, by tightness class and endurance. | No |
| NACE MR0175 / ISO 15156 | Material and hardness limits for sour service in the presence of wet H₂S. | No |
| ISO 5208 | Allowable seat leakage rates, by rate class, for the closure test. | Yes |
| ASTM G48 | Pitting and crevice corrosion test in ferric chloride. How an alloy claim gets proven. | No |
| WRAS / NSF 61 | Approval of materials in contact with drinking water. | No |
| EN 10204 | Inspection document type: 2.2 non-specific, 3.1 mill-certified, 3.2 third-party. | Yes |
How an enquiry is worked.
We do not sell parts. We start with the service condition, then the valve, then the paperwork, then the supply. Technical support, testing and maintenance →
State the condition
Medium, operating and design pressure, operating and design temperature, size and end connection. Four things; everything else follows from them.
Resolve the limits
Pressure class against the rating table at temperature, body material against the medium, seat and stem against the shut-off and emission class the duty demands.
Name the documents
The design standard, the test standard, the inspection document type and any type-test qualification: fire-safe, fugitive emission, sour service. Settled before a quotation is raised.
Supply and support
Selection across six product lines, then testing, maintenance and repair through the valve's service life. Price, lead time and availability are confirmed per enquiry.

Guides for engineers who specify first.
Four territories, each with a pillar guide and the articles beneath it. All guides → · FAQ →
Valve selection by standard
Which class, material and standard a service condition needs, before the enquiry.
District cooling & HVAC
PICV or balancing, ΔT, chiller isolation: the chilled-water questions, written for the Gulf.
Steam, pressure & protection
Sizing a PRV, choosing a steam trap, relief versus safety: the questions with numbers in them.
Sourcing & documentation
EN 10204 3.1, the API monogram, test reports: what to demand from a valve supplier in Dubai.
Enquiry Dubai
Tell us the service condition. We will tell you the valve.
Medium, pressure, temperature, size. Price, lead time and availability are confirmed per enquiry, never assumed.
Send an enquiry